- DirectSOFT5 is the new and improved version of the Windows-based PLC programming package. With many new instructions, programming is now easier, quicker and more intuitive than ever. Great for light programming or for learning to program (tutorial included). Create your own utilities, games, business apps and more. Large online community.
- DirectSOFT 5 Tips Automation Direct's DirectSOFT5 programming software has a Tip of the Day feature. There's some good tips in there so I've reproduced them here for easier reading.
MANUAL REVISIONS Please include the Manual Number and the Manual Issue, both shown below, when communicating with Technical Support regarding this publication. Title: DirectSOFT 5 Programming Software User Manual.
1. Configuring DirectLogic PLCs in DirectSoft Software
1. Launch DirectSOFT programming software.
2. Click the New Link icon to start the Link Wizard.
3. Select the COM port that is connected to the PLC, then click Next.
4. Select your PLC family type. For example, since I am using DirectLOGIC 205 DL-240CPU, therefore I choose 105/205/405 Family. If you are unsure, but know the communications protocol it uses, select **Not Sure** from the list.
5. Select the communication protocol and PLC address. In this example I am going to use K Sequence protocol and PLC address 1 since this is the only PLC I am using. Click Next to connect to the PLC.
6. DirectSOFT will attempt to establish communication and configure PLC settings appropriately.
7. After auto-configuration is completed, enter a name to the Link Name field, which can be any string. The Link Description field is optional. Write down the configuration settings for future references. Verify settings and click Finish after you are done, or you can go back and change any settings as necessary.
8. Now you should be able to see the new link on the Launch screen. Make sure the LED is green. If it is red, then there is a problem.
9. Double-click the new link to launch DirectSOFT programming window to create and/or monitor the Ladder Logic program stored in the PLC memory.
10. To view the Setup Secondary Communications Port configuration, selectPLC >> Setup >> Setup Sec. Comm Port.
To view I/O Configuration, select PLC >> Configure I/O.
2. Click the New Link icon to start the Link Wizard.
3. Select the COM port that is connected to the PLC, then click Next.
4. Select your PLC family type. For example, since I am using DirectLOGIC 205 DL-240CPU, therefore I choose 105/205/405 Family. If you are unsure, but know the communications protocol it uses, select **Not Sure** from the list.
5. Select the communication protocol and PLC address. In this example I am going to use K Sequence protocol and PLC address 1 since this is the only PLC I am using. Click Next to connect to the PLC.
6. DirectSOFT will attempt to establish communication and configure PLC settings appropriately.
7. After auto-configuration is completed, enter a name to the Link Name field, which can be any string. The Link Description field is optional. Write down the configuration settings for future references. Verify settings and click Finish after you are done, or you can go back and change any settings as necessary.
8. Now you should be able to see the new link on the Launch screen. Make sure the LED is green. If it is red, then there is a problem.
9. Double-click the new link to launch DirectSOFT programming window to create and/or monitor the Ladder Logic program stored in the PLC memory.
10. To view the Setup Secondary Communications Port configuration, selectPLC >> Setup >> Setup Sec. Comm Port.
To view I/O Configuration, select PLC >> Configure I/O.
2. Configuring DirectLogic PLCs in Lookout and Lookout Protocol Drivers
1. Close DirectSOFT and any other software currently communicating with the PLC, and start Lookout or Lookout Protocol Drivers.
2. Create a new object by selecting Object >> Create.
3. Select the DL205 or the DL405 object, depending on the type of your PLC.
4. Clone all settings from DirectSOFT. For more information about configuring the PLC using Lower port (n) protocol, refer to the KnowledgeBase entry regarding this matter.
By now, the PLC should have been configured in Lookout or Lookout Protocol Drivers and you should be able to access the PLC registers.
Both Lookout and Lookout Protocol Drivers are OPC Servers, therefore you can connect to both of them from any OPC Client, such as ServerExplorer and LabVIEW. For an example of using ServerExplorer and LabVIEW, refer to Connecting ServerExplorer to Lookout.
For more information about the DirectLogic object data members, refer to the Lookout Help.
AutomationDirect | Direct Sales in US and Canada | 1-800-633-0405
Software Demos
C-more Demo Programming Software
Please visit this page to download C-more Programming Software. Install without entering a keycode to activate the demo version. Refer to the 'Readme' document within the ZIP file for details about the Demo version. To order a keycode in order to activate the full verison, please visit our online store.
C-more Micro Programming Software
The C-More Micro programming software can be downloaded for free from our Web site. This is the full-featured C-More Micro programming software and not a demo version.
Download and System Requirements Here:
CLICK PLC Programming Software
The CLICK PLC programming software can be downloaded for free from our Web site and provides an intuitive programming tool that will get you up and running quickly. This is the full-featured CLICK programming software and not a demo version.
![Directsoft Directsoft](https://docplayer.net/docs-images/41/22457723/images/page_9.jpg)
Download and System Requirements Here:
DataNet OPC Web-based Data Monitoring Software
DataNet OPC Demo (File size 10.4 MB)
The above file installs as an unregistered demo version of the complete DataNet OPC software package. The demo is a fully functioning Web based data monitoring and logging software that will run for three days. After three days the trial version will expire and give you a message window when you try to start the software.
DirectSOFT6
Use this file for these part numbers:
- PC-DSOFT6: DirectSOFT6 Programming Software
- PC-R60-U: DirectSOFT6 upgrade from any previous version of DirectSOFT
- PC-DS100: DirectSOFT100: Free version of DirectSOFT6 limited to 100 words
Download Here:
Installing DirectSOFT100 (PC-DS100)
![Directsoft 5 tutorial pdf Directsoft 5 tutorial pdf](https://s-media-cache-ak0.pinimg.com/736x/51/5f/87/515f87a55aeb439ab90d1041d70f512f.jpg)
DirectSOFT100 gives you the same features as the full version of DirectSOFT6 but allows only 100 Words of ladder code to be downloaded to the PLC. Programs DL05/06/105/205/305/405 systems. (Order programming cable separately.) A keycode is not required to install DirectSOFT100.
Installing DirectSOFT6 (PC-DSOFT6 and PC-R60-U)
To activate PC-DSOFT6 (the full version of DirectSOFT6) or the PC-R60-U upgrade, enter the keycode (which you received upon purchase) during installation.
Recommended PC requirements
Following are the recommended system requirements for running DirectSOFT6 on a PC:
Following are the recommended system requirements for running DirectSOFT6 on a PC:
- 1 GHz CPU
- CD-ROM for loading software
- Windows 10, Windows 8.1 - 64 bit, Windows 8.1 - 32 bit, Windows 8 - 64 bit, Windows 8 - 32 bit, Windows 7 - 64 bit, Windows 7 - 32 bit, Windows Vista - 64 bit, Windows Vista - 32 bit, Windows XP
No DOS, OS/2, MacIntosh, LINUX or UNIX versions, or 16-bit versions available. Windows 8 RT not supported. - 512 MB RAM and 50 MB free hard disk space
- CD-ROM for loading software. At least one unused serial communications port or USB port using our USB-RS232,USB-to-serial adapter and/or 10-Base-T or 10/100-Base-T Ethernet network card.
- Color SVGA monitor (1024 x 768)
Do-more Designer Programming Software
Do-more Designer programming software for the Do-more PLC can be downloaded for free from our Web site. This is the full-featured Do-more programming software and not a demo version.
Download and System Requirements Here:
GSoft
GSoft is now free to download. There is no longer a demo version.
KEPDirect OPC Server Download
Download KEPDirect Servers (v5.11.263.0) Demo (File size 29.2 MB)
This file is the full package download for our KEPDirect OPC Server. The software installs as a demo version prior to registration at which time you will receive a file to unlock your unlimited version. Our latest KEPDirect package includes all drivers and help file documentation for connection to the DirectLOGIC PLCs and EBCs, the Productivity3000 PAC, and our Ethernet-enabled GS and Durapulse drives. Without a keycode for a purchased software license, the server will run for two hours at a time.
Minimum PC requirements
2.0 GHz Processor, 1 GB installed RAM, 180 MB available disk space, Ethernet Card (required for Ethernet drivers or serial drivers that utilize Ethernet encapsulation), Super VGA (800 x 600) or higher resolution video adapter and monitor, Keyboard and Microsoft mouse or compatible pointing device
2.0 GHz Processor, 1 GB installed RAM, 180 MB available disk space, Ethernet Card (required for Ethernet drivers or serial drivers that utilize Ethernet encapsulation), Super VGA (800 x 600) or higher resolution video adapter and monitor, Keyboard and Microsoft mouse or compatible pointing device
Minimum PC requirements
Windows 8, Windows 7 (Professional, Enterprise, and Ultimate), Windows Server 2012, Windows Server 2008 R2, Windows Server 2008, Windows Vista (Business, Enterprise, and Ultimate), Windows Server 2003 (Service Pack 2), Windows XP Professional (Service Pack 2).
Windows 8, Windows 7 (Professional, Enterprise, and Ultimate), Windows Server 2012, Windows Server 2008 R2, Windows Server 2008, Windows Vista (Business, Enterprise, and Ultimate), Windows Server 2003 (Service Pack 2), Windows XP Professional (Service Pack 2).
Note: When installed on a 64 bit operating system, the application will run in a subsystem of Windows called WOW64 (Windows-on-Windows 64 bit). WOW64 is included on all 64 bit versions of Windows and is designed to make differences between the operating systems transparent to the user.
Productivity Suite Programming Software
The Productivity Suite programming software is a full-featured programming tool for the Productivity Series controllers. This is a FREE download from our Web site and provides an intuitive programming tool that will get you up and running quickly. This is the complete Productivity Series programming package and not a demo version.
An optional Demo version install of the DataWorx P3K database connectivity software is also included with the Productivity Suite install.
Download and System Requirements Here:
SOLO Temperature Controllers
The SOLO Temperature Controllers configuration and monitoring software is a free download.
SureServo PRO
SureServo Pro software is now free to download. There is no longer a demo version. Please visit this page to download the most recent version of SureServo PRO.
SureMotion Pro
SureMotion Pro software is free to download. SureMotion Pro completely replaces SureStep Pro. Please visit this page to download the most recent version of SureMotion Pro.
Think & Do PC Based Control Software
Download Here:
Think & Do Version 8.1.0 (File size 225 MB)
This is the same program received when purchasing Think & Do PC Based Control Software, part numbers PC-TD8-USB or PC-TD8-WEB4-USB.
The purchased software will arrive with a software CD, a Quick Start Guide and a USB Runtime hardware key that will remove the limitations of demonstration mode. In demonstration mode, the Runtime use is limited to 30 minute sessions. The development environment is not restricted and provides a free WinPLC programming pack.
ViewMarq Configuration Software
ViewMarq configuration software is required to program ViewMarq LED message displays. This is a FREE download from our Web site and is not a demo version.